EP1xxx | EtherCAT Box, digital input

The EP1xxx digital input modules are intended for the acquisition of digital/binary signals. Typically, these are mechanical contacts such as break contacts or make contacts, electronic sensors such as inductive proximity switches, optical sensors or other methods in order to generate a low/high signal in the sense of control technology. This signal is transmitted via EtherCAT to the higher-level automation device for further processing or for the control of the machine/plant. The module variants differ by different signal thresholds, number of channels, connection options and/or input filter times. The portfolio is rounded off by additional modules with XFC timestamp or safety as well as combined input/output modules.

Your selection:
    • EP1008-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M8

      EP1008-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M8Preferred type

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M8
    • EP1008-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M12

      EP1008-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M12

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M12
    • EP1008-0022 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M12

      EP1008-0022 | EtherCAT Box, 8-channel digital input, 24 V DC, 3 ms, M12

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M12
    • EP1018-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M8

      EP1018-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M8

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      M8
    • EP1018-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M12

      EP1018-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M12

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      M12
    • EP1098-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, ground switching, M8

      EP1098-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, ground switching, M8

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M8
    • EP1258-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 1 µs, M8, timestamp

      EP1258-0001 | EtherCAT Box, 8-channel digital input, 24 V DC, 1 µs, M8, timestamp

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      1.0 µs typ.
      Connection method (signal):
      M8
    • EP1258-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M12, timestamp

      EP1258-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, 10 µs, M12, timestamp

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      1.0 µs typ.
      Connection method (signal):
      M12
    • EP1258-0502 | EtherCAT Box, 8-channel digital input, 24 V DC, 1 µs, M12, multi-timestamp

      EP1258-0502 | EtherCAT Box, 8-channel digital input, 24 V DC, 1 µs, M12, multi-timestampNew

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      1.0 µs typ.
      Connection method (signal):
      M12
    • EP1518-0002 | EtherCAT Box, 2-channel digital input, counter, 24 V DC, 1 kHz, M12

      EP1518-0002 | EtherCAT Box, 2-channel digital input, counter, 24 V DC, 1 kHz, M12

      Channels:
      8
      Value range (digital/encoder):
      24 V
      Filter (digital):
      adjustable
      Connection method (signal):
      M12
    • EP1809-0021 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M8

      EP1809-0021 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M8Preferred type

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M8
    • EP1809-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M12

      EP1809-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M12

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M12
    • EP1809-0042 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M12

      EP1809-0042 | EtherCAT Box, 16-channel digital input, 24 V DC, 3 ms, M12

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      3.0 ms typ.
      Connection method (signal):
      M12
    • EP1816-0003 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, IP20 connector

      EP1816-0003 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, IP20 connector

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      spring-loaded technique
    • EP1816-0008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub

      EP1816-0008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      D-sub
    • EP1816-0703 | EtherCAT Box, 16-channel digital input, ID switch, 24 V DC, 10 µs, IP20 connector

      EP1816-0703 | EtherCAT Box, 16-channel digital input, ID switch, 24 V DC, 10 µs, IP20 connectorNew

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      spring-loaded technique
    • EP1816-1008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub, changed pin assignment

      EP1816-1008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub, changed pin assignment

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      D-sub
    • EP1816-3008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub, 2 x 3-axis accelerometers

      EP1816-3008 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, D-sub, 2 x 3-axis accelerometers

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      D-sub
    • EP1819-0005 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M8, 4-pin

      EP1819-0005 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M8, 4-pin

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      M8
    • EP1819-0021 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M8

      EP1819-0021 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M8

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      M8
    • EP1819-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M12

      EP1819-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, 10 µs, M12

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      10 µs typ.
      Connection method (signal):
      M12
    • EP1839-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, M12, with diagnostics

      EP1839-0022 | EtherCAT Box, 16-channel digital input, 24 V DC, M12, with diagnostics

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      adjustable
      Connection method (signal):
      M12
    • EP1839-0042 | EtherCAT Box, 16-channel digital input, 24 V DC, M12, with diagnostics

      EP1839-0042 | EtherCAT Box, 16-channel digital input, 24 V DC, M12, with diagnostics

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Filter (digital):
      adjustable
      Connection method (signal):
      M12
    • EP1859-0042 | EtherCAT Box, 8-channel digital input + 8-channel digital output, 24 V DC, 3 ms, 0.5 A, M12

      EP1859-0042 | EtherCAT Box, 8-channel digital input + 8-channel digital output, 24 V DC, 3 ms, 0.5 A, M12

      Channels:
      16
      Value range (digital/encoder):
      24 V
      Output current:
      0.5 A
      Connection method (signal):
      M12
    • EP1908-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, M12, TwinSAFE

      EP1908-0002 | EtherCAT Box, 8-channel digital input, 24 V DC, M12, TwinSAFE

      Channels:
      8
      Connection method (signal):
      M12
      TwinSAFE type:
      input